  "schemaVersion": 1,
  "capturedAt": "2026-10-29T10:31:13.624Z",
  "sha256": "c12dc3b9058b7f68f9960d25586601763a70c5bbcd243a8a445c07fde9d15f8b",
  "work": {
    "id": "TAP-RDN-0019",
    "type": "RDN",
    "kind": "note",
    "key": "laborde-2017",
    "locale": "en",
    "path": "/research/laborde-2017/",
    "title": "TAP reading note: Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research - Recommendations for Experiment Planning, Data Analysis, and Data Reporting",
    "description": "These recommendations distinguish resting, reactivity and recovery measurements. Raw ECG, recording length, artefact handling and respiration all affect interpretation. Recordings shorter than the commonly used five-minute window need metric-specific validation of comparability.",
    "rights": "© The Allostasis Project. All rights reserved. Reproduction or adaptation requires separate permission, subject to applicable legal exceptions.",
    "version": "0.3",
    "updatedAt": "2026-10-29",
    "editorial": {
      "contentType": "evidence-review",
      "reviewState": "draft",
      "reviewedAt": null,
      "reviewedVersion": null,
      "updatedAt": "2026-10-29",
      "version": "0.3",
      "author": null,
      "reviewer": null,
      "workflow": {
        "ai": {
          "usage": "used",
          "system": "OpenAI Codex",
          "scope": "Assisted source comparison, evidence extraction and bilingual research-note preparation. The materials consulted and unresolved scientific issues are specified in each note.",
          "version": "0.3",
          "tasks": [
            "Source comparison and evidence extraction",
            "Bilingual research-note drafting and editorial comparison"
          ]
        }
      },
      "revisions": [
        {
          "date": "2026-10-27",
          "version": "0.2",
          "description": "Reframed scope in terms of study design, population, outcomes and observation window."
        },
        {
          "date": "2026-10-29",
          "version": "0.3",
          "description": "Added specific limits concerning recording windows, respiration and artefact processing."
        }
      ]
    },
    "original": {
      "id": "laborde-2017",
      "title": "Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research - Recommendations for Experiment Planning, Data Analysis, and Data Reporting",
      "authors": "Sylvain Laborde · Emma Mosley · Julian F. Thayer",
      "journal": "Frontiers in Psychology",
      "year": "2017",
      "url": "https://doi.org/10.3389/fpsyg.2017.00213",
      "doi": "10.3389/fpsyg.2017.00213",
      "pmid": "28265249"
    },
    "references": [
      {
        "id": "laborde-2017",
        "title": "Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research - Recommendations for Experiment Planning, Data Analysis, and Data Reporting",
        "authors": "Sylvain Laborde · Emma Mosley · Julian F. Thayer",
        "journal": "Frontiers in Psychology",
        "year": "2017",
        "url": "https://doi.org/10.3389/fpsyg.2017.00213",
        "doi": "10.3389/fpsyg.2017.00213",
        "pmid": "28265249"
      }
    ],
    "sections": [
      {
        "id": "finding",
        "title": "What the study found",
        "paragraphs": [
          "These recommendations distinguish resting, reactivity and recovery measurements. Raw ECG, recording length, artefact handling and respiration all affect interpretation. Recordings shorter than the commonly used five-minute window need metric-specific validation of comparability."
        ]
      },
      {
        "id": "limits",
        "title": "Scope & limitations",
        "paragraphs": [
          "Methodological recommendations for psychophysiological HRV research; no new clinical trial sample.",
          "Monitoring respiration does not imply automatic respiratory adjustment for every resting spontaneous-breathing recording; task-related breathing changes require care. Reporting guidance does not validate a device or clinical predictor, and filter settings cannot be transferred without checking."
        ]
      },
      {
        "id": "sample",
        "title": "Population & sample",
        "paragraphs": [
          "Methodological recommendations for psychophysiological HRV research; no new clinical trial sample."
        ]
      },
      {
        "id": "exposure",
        "title": "Exposure or intervention",
        "paragraphs": [
          "Study design, rest/reactivity/recovery, ECG and interbeat intervals, signal cleaning and statistical reporting."
        ]
      },
      {
        "id": "outcomes",
        "title": "Outcomes",
        "paragraphs": [
          "Interpretability and reproducibility of HRV measures related to cardiac vagal regulation."
        ]
      },
      {
        "id": "duration",
        "title": "Time frame",
        "paragraphs": [
          "Five minutes is a common short-recording reference; other durations require metric- and question-specific validation."
        ]
      },
      {
        "id": "funding",
        "title": "Research funding",
        "paragraphs": [
          "German Sport University Cologne, grant HIFF 920147."
        ]
      },
      {
        "id": "conflicts",
        "title": "Research conflicts of interest",
        "paragraphs": [
          "The authors declared no commercial or financial relationships that could constitute a conflict."
        ]
      },
      {
        "id": "basis",
        "title": "Reading scope",
        "paragraphs": [
          "Full-text rest/reactivity/recovery framework, equipment, recording length, artefacts and respiration. Particular devices and windows require corresponding independent validation studies."
        ],
        "links": [
          {
            "label": "Full text in PubMed Central",
            "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5316555/"
          }
        ]
      }
    ]
  }
}