  "schemaVersion": 1,
  "capturedAt": "2026-10-29T10:31:13.708Z",
  "sha256": "a29a2dc68c87b28fd1d0e6b4f234bdd8c56d8f0ad37ed909e54b782d5d3bf6e8",
  "work": {
    "id": "TAP-RDN-0019",
    "type": "RDN",
    "kind": "note",
    "key": "laborde-2017",
    "locale": "zh",
    "path": "/zh/research/laborde-2017/",
    "title": "TAP 导读: Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research - Recommendations for Experiment Planning, Data Analysis, and Data Reporting",
    "description": "这份方法建议把静息、反应和恢复分开，说明HRV研究应记录哪些条件。原始ECG、记录长度、伪差处理和呼吸信息共同决定一个数值能否被合理解释；短于常用五分钟窗口的记录，需要按具体指标验证可比性。",
    "rights": "© The Allostasis Project。保留所有权利。除法律允许的例外外，转载或改编需另行授权。",
    "version": "0.3",
    "updatedAt": "2026-10-29",
    "editorial": {
      "contentType": "evidence-review",
      "reviewState": "draft",
      "reviewedAt": null,
      "reviewedVersion": null,
      "updatedAt": "2026-10-29",
      "version": "0.3",
      "author": null,
      "reviewer": null,
      "workflow": {
        "ai": {
          "usage": "used",
          "system": "OpenAI Codex",
          "scope": "Assisted source comparison, evidence extraction and bilingual research-note preparation. The materials consulted and unresolved scientific issues are specified in each note.",
          "version": "0.3",
          "tasks": [
            "Source comparison and evidence extraction",
            "Bilingual research-note drafting and editorial comparison"
          ]
        }
      },
      "revisions": [
        {
          "date": "2026-10-27",
          "version": "0.2",
          "description": "按研究设计、人群、结局与观察窗口重写适用范围说明。"
        },
        {
          "date": "2026-10-29",
          "version": "0.3",
          "description": "补充记录窗口、呼吸与伪差处理的具体解释边界。"
        }
      ]
    },
    "original": {
      "id": "laborde-2017",
      "title": "Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research - Recommendations for Experiment Planning, Data Analysis, and Data Reporting",
      "authors": "Sylvain Laborde · Emma Mosley · Julian F. Thayer",
      "journal": "Frontiers in Psychology",
      "year": "2017",
      "url": "https://doi.org/10.3389/fpsyg.2017.00213",
      "doi": "10.3389/fpsyg.2017.00213",
      "pmid": "28265249"
    },
    "references": [
      {
        "id": "laborde-2017",
        "title": "Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research - Recommendations for Experiment Planning, Data Analysis, and Data Reporting",
        "authors": "Sylvain Laborde · Emma Mosley · Julian F. Thayer",
        "journal": "Frontiers in Psychology",
        "year": "2017",
        "url": "https://doi.org/10.3389/fpsyg.2017.00213",
        "doi": "10.3389/fpsyg.2017.00213",
        "pmid": "28265249"
      }
    ],
    "sections": [
      {
        "id": "finding",
        "title": "研究发现",
        "paragraphs": [
          "这份方法建议把静息、反应和恢复分开，说明HRV研究应记录哪些条件。原始ECG、记录长度、伪差处理和呼吸信息共同决定一个数值能否被合理解释；短于常用五分钟窗口的记录，需要按具体指标验证可比性。"
        ]
      },
      {
        "id": "limits",
        "title": "范围与局限",
        "paragraphs": [
          "心理生理学HRV研究的方法建议；无新的临床试验样本。",
          "建议监测呼吸，并不等于所有静息自然呼吸记录都应常规做呼吸校正；任务改变呼吸时需特别谨慎。报告规范不能替代设备一致性或临床预测验证，自动滤波参数也不能不经验证直接照搬。"
        ]
      },
      {
        "id": "sample",
        "title": "研究人群与样本",
        "paragraphs": [
          "心理生理学HRV研究的方法建议；无新的临床试验样本。"
        ]
      },
      {
        "id": "exposure",
        "title": "暴露或干预",
        "paragraphs": [
          "实验设计、静息/反应/恢复记录、ECG与心搏间期、信号清理和统计报告。"
        ]
      },
      {
        "id": "outcomes",
        "title": "观察结局",
        "paragraphs": [
          "心脏迷走调节相关HRV指标的可解释性与可复现性。"
        ]
      },
      {
        "id": "duration",
        "title": "时间范围",
        "paragraphs": [
          "短时记录常以五分钟为比较基准；其他时长依指标和研究问题验证。"
        ]
      },
      {
        "id": "funding",
        "title": "研究资金来源",
        "paragraphs": [
          "德国科隆体育大学，资助编号HIFF 920147。"
        ]
      },
      {
        "id": "conflicts",
        "title": "研究利益关系",
        "paragraphs": [
          "作者声明不存在可能构成利益冲突的商业或财务关系。"
        ]
      },
      {
        "id": "basis",
        "title": "导读范围",
        "paragraphs": [
          "全文静息/反应/恢复框架、设备、记录长度、伪差及呼吸部分；具体设备与窗口仍需对应的独立验证研究。"
        ],
        "links": [
          {
            "label": "PubMed Central全文",
            "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5316555/"
          }
        ]
      }
    ]
  }
}