RMSSD and SDNN can both be displayed in milliseconds, but they summarize different aspects of beat-to-beat variation. A proprietary recovery score can combine several inputs and is a different quantity again.[1][2]

Three things that should not share one “normal” tableDuration and processing still matter within each metric.[1][2]
DisplayWhat it describesBefore comparing
RMSSD, msSuccessive differences between normal beat intervals.Confirm the recording window, conditions and processing.
SDNN, msThe spread of normal beat intervals over a recording.A short sample and a 24-hour recording are not interchangeable.
Recovery score, pointsA manufacturer-defined combination of inputs.Check the score’s definition and validation, not an HRV reference table.

03Why do online normal-value tables disagree?

Reference studies have used recordings from seconds to 24 hours, different ages and different criteria for “healthy”. Even studies using the same metric differ in time of day, equipment, activity and handling of medication or other influences. A population average is not an individual diagnostic cut-off.[1]

The 2025 review searched through November 2022. Its publication date should not be mistaken for a search that included every study through 2025. It supports caution about a universal range, while compatible reference studies may still be useful for a defined population and protocol.[1]

04How to make a personal comparison more useful

Keep the metric and device consistent. For a deliberate resting measurement, also keep time of day, posture, resting period and recording length comparable. For an overnight device, use the manufacturer’s defined overnight series consistently. Record changes in device, firmware or method so that a jump is not automatically attributed to your body.[2][3]

Look at repeated valid readings alongside sleep, illness, activity and how you feel. Do not discard a low value just because it is unwelcome; identify missing or poor-quality recordings separately. Device-specific baseline windows differ, and one week is not a validated universal minimum for a stable baseline.

05The same 40 ms can lead to different questions

These are invented values, not reference ranges or health thresholds.

Check comparability before interpretationTeaching examples; no numerical change here diagnoses a problem.
SituationWhat the number permitsWhat it does not permit
Usually 35–45 ms; today 40 msIt falls within this person’s recent observed values, if the method matches.Calling the person healthy or fully recovered.
Usually 65–75 ms; today 40 msCheck measurement conditions and whether the change persists.Diagnosing the cause from one reading.
Old device: 40 ms; new device: 55 msCheck metric, duration and agreement between methods.Concluding that recovery improved by 15 ms.

06Can a wearable be compared with an ECG?

Agreement is a question for a particular device, algorithm, metric and setting. A 2025 validation study compared five wearables with a chest-strap ECG reference across repeated nights in 13 adults. Agreement varied by device; hundreds of nights did not mean hundreds of independent participants.[3]

That study tested basic nocturnal HRV measures, not the validity of every composite readiness score. Its reading note also retains a numerical inconsistency in one device’s bias and agreement limits. It should not supply a precise personal correction factor.[3]

07A one-week observation sheet

Use the optional sheet to organize existing readings, not to chase a higher score. Write the metric, device and recording conditions first; then note a daily value, signal-quality issues and relevant context. Leaving a blank for missing data is better than turning it into zero.

At the end of seven days, ask whether the measurements were comparable and whether an apparent change coincided with a changed routine or method. The sheet does not calculate a diagnosis, a normal range or a validated recovery score. Seven days may be insufficient to describe your usual variation.

The CSV opens in a spreadsheet and contains no upload function. Keep completed copies private; there is no need to enter your name or medical details.

08What can you do with a change?

First check the measurement. Then consider the pattern and context. A persistent unexplained change or concerning symptoms deserves clinical interpretation rather than a conclusion based on a watch score. A reassuring HRV value should not override symptoms.

If you are testing a routine, choose a relevant outcome too: for example, sleep continuity, tolerability of a usual activity or a specified training measure. Raising HRV alone does not prove better recovery or a treatment effect.[2]

09Sources and limits

This guide uses the reference-value review, psychophysiology recommendations and the linked wearable validation study. A 2026 methodological review also argues for clear reporting of signals, windows, respiration and artefacts; its checklist is author-proposed, not an externally validated clinical score.[4] The observation sheet is TAP’s educational aid, not a validated instrument.

10Funding and interests

Brozat and colleagues report no external funding and no conflicts. Laborde reports German Sport University Cologne HIFF 920147 and no commercial or financial conflicts. Dial reports US Air Force Research Laboratory S-194-11T-001 and no competing interests. Kazdagli’s funding and interest declarations have not been fully verified. Consulted sections and remaining uncertainties are recorded in the source notes.

11References

  1. Systematic Review on HRV Reference Values

    Maximillian Brozat; Irina Böckelmann; Stefan Sammito
    Journal of Cardiovascular Development and Disease · 2025
    Study record & citations

  2. Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research - Recommendations for Experiment Planning, Data Analysis, and Data Reporting

    Sylvain Laborde · Emma Mosley · Julian F. Thayer
    Frontiers in Psychology · 2017
    Study record & citations

  3. Validation of nocturnal resting heart rate and heart rate variability in consumer wearables

    Dial MB · Hollander ME · Vatne EA · Emerson AM · Edwards NA · Hagen JA
    Physiological Reports · 2025
    Study record & citations

  4. A reporting checklist for human and animal heart rate variability research

    Kazdağlı H · Özel HF
    Pflügers Archiv - European Journal of Physiology · 2026
    Study record & citations

Follow the connections.

Explore all questions
START WITH A QUESTION

Recovery & HRV

Editorial & review record

Record for v1.0 · Updated

Editorial responsibility: TAP Editorial Team

Editorial note

Under the editorial responsibility of the TAP Editorial Team, this publication used AI assistance for content organization and editing.

Download detailed editorial record (JSON) ↓

How responsibilities and review are recorded ↗